Fire Door Inspection Checklist (UK 2026)
Fire Door Inspection Checklist — Why It Matters
Under the Fire Safety (England) Regulations 2022, the Responsible Person for any residential building over 11 m must inspect communal fire doors quarterly and flat entrance doors annually. Commercial premises typically need 6-monthly checks under the Fire Safety Order 2005.
This checklist is designed to be used during in-house "common-sense" checks. It is not a substitute for a competent BM TRADA Q-Mark certified inspection — but it will help you spot the obvious failures before a fire risk assessor or enforcing officer does.
The 12-Point Fire Door Inspection Checklist
1. Certification Label or Plug
- Is there a top-edge plug or label confirming the fire rating?
- Is the rating (FD30, FD30S, FD60) clearly readable?
- If there's no label, mark the door for invasive inspection — see our guide to fire door labels.
2. Door Leaf Condition
- Is the leaf free of large dents, splits or impact damage?
- Has it been cut down or modified after installation? (Trimming over the manufacturer's tolerance voids certification.)
- Has it been painted in a way that bridges the intumescent strips?
3. Gaps and Tolerances (the 3 mm Rule)
Use a 3 mm gauge or a £1 coin (around 3 mm thick):
- Gap between leaf and frame on the head: ≤ 3 mm
- Gap between leaf and frame on the sides: ≤ 3 mm
- Gap at the threshold: typically 8–10 mm (or per manufacturer)
Anything over 3 mm at head or sides is a fail.
4. Intumescent Strips
- Are intumescent strips fitted in the frame or leaf?
- Are they continuous around head and both sides?
- Are they undamaged, unpainted, and seated correctly in the routed groove?
5. Smoke Seals (FD30S / FD60S Doors)
- Are brush or fin smoke seals fitted alongside the intumescent strip?
- Are they making contact with the door leaf when closed?
- Are they free of damage, paint or compression set?
6. Hinges
- Are there at least three CE-marked fire hinges?
- Are all hinge screws fully tightened?
- Is there any visible movement or "drop" when the door is open at 90°?
7. Self-Closing Device
Open the door to 5° from the frame and let it go:
- Does it fully latch into the keep without manual intervention?
- Is the closer free of leaks, fully attached and CE-marked?
- Is it set to a force at least matching the door size (typically size 3 or 4)?
8. Latches and Locks
- Does the latch engage cleanly and hold the door shut?
- Are locks and latches fire-rated and CE-marked?
- Is any unused mortice (e.g. an old lock pocket) properly fire-stopped?
9. Glazing and Vision Panels
- Is the glazing fire-rated (look for an etched mark in the corner)?
- Are intumescent beads fitted around the glazing?
- Are the beadings undamaged and properly fixed?
10. Signage
- Is the correct sign present? "Fire Door — Keep Shut" on self-closing communal doors, "Fire Door — Keep Locked Shut" on locked risk rooms
- Is it on the correct face of the door?
- Is it BS 5499 / BS EN ISO 7010 compliant?
11. Hold-Open Devices
- If the door is held open, is it via an electromagnetic hold-open device linked to the fire alarm?
- Wedges, hooks, fire extinguishers and chairs are not legal. See our hold-open devices guide.
12. Architraves and Wall Interface
- Are the Architraves properly fixed?
- Is the gap between the frame and the structural opening fire-stopped (mineral wool or fire-rated mastic — not standard expanding foam)?
What to Do With Your Findings
Document everything, ideally with photos. If you find:
- Minor defects (e.g. missing signage, worn smoke seals): can usually be remediated under our Q-Mark scheme.
- Major defects (gap >3 mm, no certification, damaged leaf): book a competent inspection and quote for remedial works or replacement.
- Multiple failing doors: arrange a full BM TRADA Q-Mark certified survey.
Why Use a Certified Inspector?
A self-check is good practice, but it does not satisfy the legal requirement for a "competent" inspection. A BM TRADA Q-Mark certified inspector:
- Carries third-party verified training and audit
- Records inspections digitally with photographic evidence per door (we use Mobiess)
- Issues defensible reports your fire risk assessor and the Building Safety Regulator can rely on
- Provides a clear remedial path under the same scheme