Fire Door Inspection Checklist (UK 2026)

Fire Door Inspection Checklist — Why It Matters

Under the Fire Safety (England) Regulations 2022, the Responsible Person for any residential building over 11 m must inspect communal fire doors quarterly and flat entrance doors annually. Commercial premises typically need 6-monthly checks under the Fire Safety Order 2005.

This checklist is designed to be used during in-house "common-sense" checks. It is not a substitute for a competent BM TRADA Q-Mark certified inspection — but it will help you spot the obvious failures before a fire risk assessor or enforcing officer does.

The 12-Point Fire Door Inspection Checklist

1. Certification Label or Plug

  • Is there a top-edge plug or label confirming the fire rating?
  • Is the rating (FD30, FD30S, FD60) clearly readable?
  • If there's no label, mark the door for invasive inspection — see our guide to fire door labels.

2. Door Leaf Condition

  • Is the leaf free of large dents, splits or impact damage?
  • Has it been cut down or modified after installation? (Trimming over the manufacturer's tolerance voids certification.)
  • Has it been painted in a way that bridges the intumescent strips?

3. Gaps and Tolerances (the 3 mm Rule)

Use a 3 mm gauge or a £1 coin (around 3 mm thick):

  • Gap between leaf and frame on the head: ≤ 3 mm
  • Gap between leaf and frame on the sides: ≤ 3 mm
  • Gap at the threshold: typically 8–10 mm (or per manufacturer)

Anything over 3 mm at head or sides is a fail.

4. Intumescent Strips

  • Are intumescent strips fitted in the frame or leaf?
  • Are they continuous around head and both sides?
  • Are they undamaged, unpainted, and seated correctly in the routed groove?

5. Smoke Seals (FD30S / FD60S Doors)

  • Are brush or fin smoke seals fitted alongside the intumescent strip?
  • Are they making contact with the door leaf when closed?
  • Are they free of damage, paint or compression set?

6. Hinges

  • Are there at least three CE-marked fire hinges?
  • Are all hinge screws fully tightened?
  • Is there any visible movement or "drop" when the door is open at 90°?

7. Self-Closing Device

Open the door to 5° from the frame and let it go:

  • Does it fully latch into the keep without manual intervention?
  • Is the closer free of leaks, fully attached and CE-marked?
  • Is it set to a force at least matching the door size (typically size 3 or 4)?

8. Latches and Locks

  • Does the latch engage cleanly and hold the door shut?
  • Are locks and latches fire-rated and CE-marked?
  • Is any unused mortice (e.g. an old lock pocket) properly fire-stopped?

9. Glazing and Vision Panels

  • Is the glazing fire-rated (look for an etched mark in the corner)?
  • Are intumescent beads fitted around the glazing?
  • Are the beadings undamaged and properly fixed?

10. Signage

  • Is the correct sign present? "Fire Door — Keep Shut" on self-closing communal doors, "Fire Door — Keep Locked Shut" on locked risk rooms
  • Is it on the correct face of the door?
  • Is it BS 5499 / BS EN ISO 7010 compliant?

11. Hold-Open Devices

  • If the door is held open, is it via an electromagnetic hold-open device linked to the fire alarm?
  • Wedges, hooks, fire extinguishers and chairs are not legal. See our hold-open devices guide.

12. Architraves and Wall Interface

  • Are the Architraves properly fixed?
  • Is the gap between the frame and the structural opening fire-stopped (mineral wool or fire-rated mastic — not standard expanding foam)?

What to Do With Your Findings

Document everything, ideally with photos. If you find:

  • Minor defects (e.g. missing signage, worn smoke seals): can usually be remediated under our Q-Mark scheme.
  • Major defects (gap >3 mm, no certification, damaged leaf): book a competent inspection and quote for remedial works or replacement.
  • Multiple failing doors: arrange a full BM TRADA Q-Mark certified survey.

Why Use a Certified Inspector?

A self-check is good practice, but it does not satisfy the legal requirement for a "competent" inspection. A BM TRADA Q-Mark certified inspector:

  • Carries third-party verified training and audit
  • Records inspections digitally with photographic evidence per door (we use Mobiess)
  • Issues defensible reports your fire risk assessor and the Building Safety Regulator can rely on
  • Provides a clear remedial path under the same scheme