Fire Door Hold-Open Devices: What's Legal and What Isn't

Fire Door Hold-Open Devices: What's Legal and What Isn't

Propping open a fire door is one of the most dangerous and common fire safety violations in the UK. We see it in almost every building we inspect — care homes, schools, offices, student accommodation, housing blocks.

The problem is understandable: fire doors can be heavy, inconvenient, and create barriers in busy corridors. But a propped-open fire door is effectively no fire door at all.

What's Illegal

The following methods of holding fire doors open are non-compliant and potentially criminal:

  • Door wedges — the classic violation
  • Fire extinguishers used as door stops
  • Hooks, latches, or chains holding doors open
  • Tying doors to radiators or furniture
  • Removing self-closing devices to prevent doors closing
  • Disabling electromagnetic hold-open devices to keep them permanently open

Under the Regulatory Reform (Fire Safety) Order 2005, the Responsible Person commits an offence if fire doors are routinely propped open. This can result in:

  • Enforcement notices from the fire service
  • Prosecution with unlimited fines
  • Imprisonment in serious cases (up to 2 years)
  • Manslaughter charges if a death results from a propped-open fire door

What's Legal: Electromagnetic Hold-Open Devices

The only legal way to hold a fire door open is with an approved electromagnetic hold-open device connected to the building's fire alarm system.

These devices work by:

  1. An electromagnet mounted on the wall or floor holds the door open during normal use
  2. When the fire alarm activates, the power to the magnet is cut
  3. The door's self-closing device pulls it shut automatically
  4. The fire door is closed and providing protection within seconds of alarm activation

Key requirements:

  • Must be connected to the building's fire detection and alarm system
  • Must release the door on alarm activation, power failure, or manual activation
  • Must be compatible with the door's self-closing device (the closer must be strong enough to close the door from the held-open position)
  • Must comply with BS EN 1155 (electromechanically operated hold-open devices)
  • Must be tested as part of the fire alarm system's maintenance routine

When to Specify Hold-Open Devices

Hold-open devices are appropriate for:

  • High-traffic corridors — where fire doors are a barrier to normal movement
  • Care homes — where residents may struggle with heavy doors
  • Schools — where children may be at risk from closing doors
  • Offices — where fire doors between departments are frequently propped
  • Accessible routes — where door closers create accessibility barriers

Cost vs Risk

A typical electromagnetic hold-open device costs approximately £150-300 fitted, including wiring to the fire alarm panel.

A fire caused by a propped-open fire door can result in:

  • Loss of life
  • Building destruction
  • Unlimited fines
  • Criminal prosecution
  • Civil liability running into millions

The investment is negligible compared to the risk.

Our Approach

At Stark Contracts, we:

  • Identify propped doors during inspections and flag them as critical defects
  • Recommend hold-open devices where doors are routinely propped
  • Install approved devices wired to the building's fire alarm system
  • Provide "Fire Door Keep Shut" signage for all fire doors
  • Brief building occupants on the dangers of propping doors open

Need hold-open devices installed? Call 01522 775570.