Fire Door Requirements for HMOs in Lincolnshire

Fire Door Requirements for HMOs in Lincolnshire

If you own or manage a House in Multiple Occupation in Lincoln, Grantham, Newark or anywhere in Lincolnshire, fire doors are a mandatory requirement.

What the Law Requires

Under the Housing Act 2004 and Management of Houses in Multiple Occupation Regulations 2006:

  • All habitable rooms must have FD30 fire doors
  • Kitchen doors must be fire-rated
  • Self-closing devices must be fitted to all fire doors
  • Intumescent strips and smoke seals must be correctly installed
  • Fire doors must be maintained in good working order

Common Issues in HMOs

We frequently find:

  • Standard doors installed instead of fire-rated doors
  • Self-closers removed by tenants (and not replaced by landlords)
  • Fire doors propped open or wedged
  • Gaps exceeding tolerances due to settlement or poor fitting

The Consequences

Non-compliance can lead to:

  • Improvement notices from the local authority
  • Civil penalties of up to £30,000
  • Prosecution with unlimited fines
  • Prohibition orders making the property unlettable

Our HMO Fire Door Service

Stark Contracts provides a complete fire door service for HMO landlords across Lincolnshire:

  1. Survey and assessment of all doors
  2. Supply and installation of certified FD30 door sets
  3. Remedial works where doors can be brought to compliance
  4. Certification and documentation for licensing applications

Licensing and Your Local Council

Most larger HMOs in Lincolnshire need a licence from the local housing authority — mandatory licensing applies to properties with five or more occupants, and several councils run additional licensing schemes for smaller HMOs. Fire door condition is one of the first things a licensing officer checks, and a failed inspection can delay or refuse a licence. Getting doors surveyed before you apply is almost always cheaper than the delays and re-inspection fees that follow a failed visit.

How Often Should HMO Fire Doors Be Checked?

The Fire Safety Order requires fire doors to be kept in efficient working order — in practice that means:

  • Monthly visual checks by the landlord or managing agent (closers, seals, damage, wedging)
  • Six-monthly or annual professional inspections, depending on footfall and licence conditions
  • Immediate action when a tenant reports a fault

Keep a written log of every check. If the worst happens, that log is your defence.

A Typical HMO Job in Lincoln

A recent four-storey HMO in Lincoln came to us with eleven non-compliant doors: three had no closers, four had painted-over intumescent strips, and two were standard domestic doors where FD30s were required. We replaced the two incorrect doors with certified FD30 doorsets at £1,199 each supply and fitted, carried out remedial works on the remaining nine, and issued photographic certification for the licence application — all inside two weeks.

Speak to our team about HMO fire door compliance — call 01522 775570.