Fire Door Inspections in Coningsby: What a BM TRADA Q-Mark Audit Actually Covers
What a Fire Door Inspection in Coningsby Really Involves
A fire door inspection is not a visual glance around the frame. In Coningsby — where raf coningsby, home of the battle of britain memorial flight, dominates the local economy — the Responsible Person under the Regulatory Reform (Fire Safety) Order 2005 has to prove, on paper, that every fire door in the building is fit to hold back fire and smoke for its rated period. That evidence is what a BM TRADA Q-Mark inspection produces.
Stark Contracts Ltd runs a 70-point audit against BS 8214:2026 (and the forthcoming BS 8214:2026). Each door is opened, closed, measured, photographed and scored pass or fail on the spot using Mobiess digital reporting software. The output is a Golden Thread record you can hand to your fire risk assessor, insurer or the local Fire and Rescue Service.
The 70-Point Checklist Applied on Coningsby Sites
Our inspectors walk each door through the same forensic sequence:
-
Leaf and frame — twist, warp, mechanical damage, correct thickness (typically 44mm for FD30, 54mm for FD60)
-
Gaps — 2–4mm around the perimeter, 3mm typical, threshold checked for smoke leakage
-
Intumescent seals — continuous, un-painted, correctly sized for the leaf
-
Cold smoke seals — present on FD30S/FD60S sets, brush or fin type in good condition
-
Hinges — CE-marked, minimum three per leaf, correctly torqued, no missing screws
-
Self-closers — closing fully into the latch from any angle without slamming
-
Latches and locks — CE-marked, engaging correctly, no domestic hardware retrofits
-
Signage — 'Fire Door Keep Shut' or 'Keep Locked' on both sides where required
-
Glazing and vision panels — certified glass, correct beading, undamaged seals
-
Fire-stopping — behind architraves, at the head and jambs, checked for voids
Why Coningsby Buildings Fail (and How We Fix It)
Across Coningsby and Tattershall, Woodhall Spa, Horncastle and Boston we see the same recurring defects: painted-over intumescent strips, propped-open doors in MoD housing providers back corridors, threshold gaps over 8mm, and non-certified hinges swapped in during a previous refurbishment. Most of these are fixable through remedial works without replacing the doorset — which keeps costs down for East Lindsey District Council landlords and estate managers.
What You Receive After a Coningsby Inspection
Within 48 hours of leaving site you get:
-
A digital PDF report with photographs of every door
-
A pass/fail schedule with defect priority levels
-
A fixed-price remedial quote for anything that failed
-
A BM TRADA Q-Mark certificate for every door that passed
Booking a Coningsby Inspection
We are around 45 minutes from our LN6 Lincoln workshop and can typically survey a Coningsby site within 5–7 working days. Non-invasive inspections and invasive checks (removing architraves to inspect fire-stopping) are quoted to scope. Contact us for a quote and booking.
Contact us for a quote and booking or call 01522 775570 to talk to a surveyor about your Coningsby building.
Related reading
fire door inspection service · remedial works · fire doors in Coningsby · book a survey