Do I Need a Fire Door Between My Garage and House? UK Rules (2026)
The short answer
Yes — if your garage is integral or attached and there is a door leading straight from the garage into the house, that door should be a fire door. Under Approved Document B (Fire Safety) Volume 1, the guidance that supports the Building Regulations 2010 in England, a door between a dwelling and an integral or attached garage should achieve E30 Sa fire and smoke performance. In everyday terms, that is an FD30S door: 30 minutes of fire resistance with smoke seals, fitted with a self-closing device.
Garages are one of the highest fire-risk spaces in a home. They hold cars, fuel, paint, solvents, lawnmowers, freezers and charging e-bikes or e-scooters, and they are usually empty of people when a fire starts. The connecting door is often the only thing standing between that fire and the hallway or kitchen your family uses to escape.
What Approved Document B expects
For a typical house with an integral or attached garage, the guidance sets out:
- Fire-resisting separation: the wall (and any floor) between garage and house should give at least 30 minutes' fire resistance (REI 30)
- Fire door rating: the connecting door should achieve E30 Sa, an FD30S doorset
- Smoke control: intumescent strips and cold smoke seals fitted around the door
- Self-closing: the door must close itself fully onto its latch from any open position
- Raised threshold: the opening should be at least 100mm above the garage floor, or the garage floor should fall away from the door, so spilt fuel cannot flow into the house
An FD30S door is a complete doorset, not just a heavy leaf. The frame, hinges, intumescent seals, latch, closer and gaps all have to match the tested specification. A fire-rated leaf hung in an ordinary frame with standard hinges will not perform as a fire door.
Does this apply to my existing house?
The Building Regulations are not generally retrospective, so an older house is not automatically breaking the law because its garage door isn't a fire door. However, the requirement does apply when:
- You build a new house or extension with an integral or attached garage
- You replace the connecting door — a like-for-like swap should not make the fire safety worse, and Building Control will expect a fire door
- You convert part of the garage or create a new opening into the house
- You sell the property — surveyors and buyers' solicitors frequently flag a non-fire-rated garage door
Even where it isn't strictly required, fitting an FD30S door is one of the most cost-effective fire safety upgrades you can make to a family home.
Landlords and rented homes
If you let the property, the picture is stricter. Local authorities assess rented homes under the Housing Health and Safety Rating System, where fire is one of the listed hazards, and HMO licences commonly require FD30S doors on escape routes, including garage connections. In HMOs and the common parts of blocks of flats, the Regulatory Reform (Fire Safety) Order 2005 also applies, and breaches can carry fines up to unlimited amounts on indictment. See our guide to landlord fire door responsibilities for more detail.
Signs your current garage door is not a fire door
- No certification label or plug on the top or hinge edge of the leaf
- No intumescent strips or smoke seals in the frame or door edge
- The door doesn't close and latch by itself
- Glazing that isn't fire-rated, or a cat flap cut into the leaf
- Gaps around the door larger than about 4mm (3mm is the target), or daylight visible under it
- Only two hinges, or hinges without CE/UKCA markings
- The door opens level with the garage floor with no step or slope
If any of these apply, the door is very unlikely to give 30 minutes of protection.
Common mistakes we see
- Removing the closer because the door is "annoying". A fire door that is wedged or propped open gives no protection.
- Fitting a fire door leaf into the old frame. The frame and seals are part of the tested system.
- Cutting the leaf down past the manufacturer's trimming limits to clear a new floor.
- Using decorative ironmongery that isn't fire-tested.
- Unsealed gaps where the frame meets the wall. These need fire-rated sealant.
What it costs
At Stark Contracts we supply and fit a certified FD30S doorset from £1,199, including the frame, seals, certified hinges, latch, overhead closer and fire door signage, installed by BM TRADA Q-Mark certified fitters. On completion you receive installation certification you can hand to Building Control, a buyer or your insurer. Where the opening is an unusual size, we assemble a bespoke pre-hung doorset in our Lincoln workshop.
Our recommendation
If you have an integral or attached garage and you are not sure what is fitted on the connecting door, get it checked. Contact us for a quote and booking. An inspection will tell you whether the door is a genuine fire door, whether it can be repaired, or whether it needs replacing.
- Book a fire door inspection
- Fire door installation
- Does my house need a fire door?
- Where are fire doors required?
Call 01522 775570 or email Enquiries@Starkcontracts.co.uk for a free survey.
This guide reflects Approved Document B (2019 edition incorporating 2020 and 2022 amendments) for England. Wales, Scotland and Northern Ireland have their own regulations. Always confirm the requirements for your project with Building Control.