What Is an Rw Rating?
Rw (weighted sound reduction index) measures how much airborne sound a door assembly blocks, expressed in decibels. Higher = better insulation:
- 28dB(Rw) — basic speech privacy, typical office partitions
- 30–32dB(Rw) — standard residential corridor doors
- 35–38dB(Rw) — hotels, student halls, care homes
- 40–44dB(Rw) — high-performance separation, music rooms, premium apartments
Ratings are tested per BS EN ISO 10140 on the complete doorset — leaf, frame, seals and threshold.
Building Regulations Approved Document E
Approved Document E sets minimum sound insulation standards for residential separating elements. While the document focuses on walls and floors, doors between dwellings and common areas typically need around 29dB(Rw) minimum — and most specifications now ask for higher.
How Acoustic Fire Doors Are Built
Achieving high Rw ratings without losing fire integrity requires:
- Denser leaf cores — heavier blanks (often 44–54mm thick)
- Drop-down acoustic seals — automatic threshold seals that engage as the door closes
- Compression seals — replacing standard intumescent/smoke seals with combined acoustic versions
- Tight tolerances — gaps must be controlled to within 3mm — see our gap requirements guide
- Correct closer adjustment — the door must seat fully every time