What Are Fire Doors Made Of? Inside a Certified FD30 Doorset
A fire door is an assembly, not a slab of timber
People picture a fire door as a heavy door. In reality it is an engineered assembly, and every part of it was present when the door was tested. Change one component and the test evidence no longer describes what is installed.
Here is what is inside a typical certified timber FD30 or FD60 doorset.
1. The core
The core provides the mass and the char resistance that buys the 30 or 60 minutes.
- Solid flaxboard or particleboard core — the most common core for FD30 and FD60 leaves. Dense, dimensionally stable and predictable in a furnace test.
- Solid timber and laminated timber core — used for higher-specification and heritage-style doors, usually engineered in laminations to control movement.
- Mineral core — very dense mineral composite, used where higher ratings, high traffic or severe-duty performance are required.
- Vermiculite and calcium silicate boards — used within composite cores and around glazed apertures.
Hollow-core and lightweight-core doors have no place here. They are the single clearest way to tell a standard door from a fire door once the label is missing.
2. Lippings
Hardwood lippings — typically 6 mm to 20 mm — are bonded to the leaf edges. They protect the core, take the ironmongery fixings, house the intumescent seals and set the limit on how much a door may legally be trimmed on site. The manufacturer's installation instructions state that limit, and it is usually only a few millimetres. Trimming beyond it voids the certification.
3. Facings
Veneer, laminate or paint-grade facings, bonded under pressure. The facing is part of the tested specification: applying a heavy new facing, a decorative panel or a non-approved finish on site can change the door's fire behaviour and invalidate the evidence.
4. Intumescent strips and smoke seals
The strips sit in routed grooves in the leaf or the frame, depending on the certification. In a fire they expand many times their original volume, sealing the gap between leaf and frame and blocking the passage of flame and hot gases.
Cold smoke seals — the brush or fin element that gives a door its "S" suffix — do a different job. They restrict cold smoke at ambient temperature, which is what actually incapacitates people escaping. Where a door is specified FD30S or FD60S, the smoke seal is not optional.
Both must be continuous, undamaged, fitted to the correct edge, and never painted over.
5. The frame
The frame is tested with the leaf and is equally part of the certification. It must be of the correct species and density, with the correct rebate depth and stop dimension, fixed at the specified centres, and with the perimeter gap packed and fire-stopped with the specified material. Expanding foam is not a fire-stopping product unless it is explicitly part of the tested specification.
Architraves cover the joint and complete the detail, but they are not the fire seal — the packing and fire-stopping behind them is.
6. Ironmongery
Every item that penetrates the leaf or supports it is part of the assembly:
- Hinges to BS EN 1935, normally three per FD30 leaf and often more on heavier FD60 leaves, with intumescent pads behind where the certification requires.
- Locks and latches fire-rated and with intumescent protection to the mortice.
- Self-closing devices to BS EN 1154 where the door must be self-closing, adjusted to close and latch from any angle — while still meeting the Approved Document M opening force limits of 30 N through the first 30 degrees and 22.5 N from 30 to 60 degrees.
- Vision panels using certified fire-resisting glazing with the correct beads, glazing tape and intumescent system.
- Letterplates, air transfer grilles and cat flaps — only where a certified, intumescent-protected product is specified. An unprotected aperture is an immediate failure.
7. The label
Finally, the part that ties it all together: a third-party certification label or plug on the top or hanging edge, with a traceable reference. It is the only practical way an inspector can confirm the door in front of them is the door that was tested.
Why this matters on site
Almost every fire door failure we record on survey comes down to a component substitution: a non-rated hinge, a site-cut vision panel, foam instead of fire-stopping, a painted-over seal, a leaf trimmed to fit. None of them look dramatic. All of them break the chain of evidence that makes the door compliant.
Stark Contracts assembles and installs certified FD30 and FD60 doorsets under BM TRADA Q-Mark certification, and surveys existing doors to BS 8214:2026.