Fire Risk Assessment Types 1, 2, 3 and 4 Explained (PAS 79)

Fire Risk Assessment Types 1–4: Which One Do You Need?

Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person for a non-domestic or multi-occupied residential building must have a suitable and sufficient Fire Risk Assessment (FRA) in place. PAS 79-1:2020 defines four assessment types — and choosing the wrong one can leave significant risk hidden.

Type 1 — Common Parts Only, Non-Destructive

The most common FRA for low- and mid-rise residential blocks. The assessor inspects:

  • Communal corridors, stairs, lobbies and plant rooms
  • Means of escape and emergency lighting
  • Fire door condition (visual, no opening of constructions)
  • Fire alarm and detection coverage in common parts

Does not inspect inside flats or behind finishes.

Type 2 — Common Parts, Destructive Sampling

Same scope as Type 1, but the assessor opens up a sample of constructions to verify compartmentation — for example removing a riser panel, lifting ceiling tiles, or inspecting service penetrations. Used where there's reason to suspect concealed defects (post-Grenfell, this is increasingly required for higher-risk buildings).

Type 3 — Common Parts + Inside Flats, Non-Destructive

Includes a sample of flats. Assessors check:

  • Flat entrance doors (both sides, where access permitted)
  • Internal layout, escape routes and detection
  • Compartmentation between dwellings

Used for higher-risk or older residential blocks, particularly HMOs and converted properties.

Type 4 — Common Parts + Inside Flats, Destructive Sampling

The most thorough. Type 3 scope plus destructive inspection inside flats. Reserved for high-risk buildings or where significant defects are suspected — and now mandatory under the Building Safety Act 2022 for many higher-risk buildings (HRBs over 18m or 7 storeys).

Stark Contracts FRA Reports

We deliver PAS 79-1:2020 compliant FRAs Types 1–4 across Lincolnshire, Nottinghamshire and the East Midlands — paired seamlessly with our fire door inspection and remedial works services.

How to Choose the Right Type

Ask three questions:

  1. How tall is the building? Over 18m or 7 storeys and you are likely looking at a Type 3 or 4 under the Building Safety Act regime.
  2. Do you suspect hidden defects? Poor historic workmanship, missing cavity barriers or unrecorded alterations point to destructive sampling (Type 2 or 4).
  3. When were the flats last looked at? If the FRA has never included inside-flat inspection, a Type 3 sample is the usual next step.

When in doubt, commission a Type 1 first — a competent assessor will tell you in the report whether the findings justify stepping up to a higher type.

What a Good FRA Report Contains

A PAS 79-1:2020 compliant report should give you:

  • A clear risk rating for the building and an action plan prioritised by risk
  • Photographic evidence of every significant finding
  • A defined review period — typically 12 months, or sooner after material change
  • Clear identification of the Responsible Person and their duties

Frequently Asked Questions

How much does a Fire Risk Assessment cost? It depends on building size and assessment type — a Type 1 for a small block of flats costs far less than a Type 4 on a high-rise. We quote fixed prices per building before any work starts.

How long does an FRA last? There is no fixed expiry, but best practice is an annual review, and immediately after any fire, refurbishment or change of use.

Can we do our own FRA? Only if you are genuinely competent — the Fire Safety Order requires a "suitable and sufficient" assessment, and an inadequate DIY assessment is worse than none because it gives false confidence.