Fire Doors for Flats: Flat Entrance Doors, Communal Doors and Landlord Duties
The two kinds of fire door in a block of flats
Flat entrance doors separate a private dwelling from the common parts. They are normally FD30S doorsets: 30 minutes' integrity plus cold smoke seals, self-closing, with certified ironmongery. Their job is to contain a fire inside a flat long enough for the stay-put or evacuation strategy to work, and to keep the communal escape route clear of smoke.
Communal doors — corridor cross-doors, lobby doors, stair doors, riser and bin store doors — protect the escape route itself. Ratings vary from FD30S in corridors to FD60 to plant and refuse rooms, always following the compartment wall they sit in.
Both are within the responsible person's remit under the Fire Safety Order 2005, and the Fire Safety Act 2021 confirmed that flat entrance doors form part of the building's fire risk assessment even though the door opens into a private home.
What the Fire Safety (England) Regulations 2022 require
Since 23 January 2023, in England:
- Buildings over 11 m in height containing two or more domestic premises: quarterly checks of fire doors in the common parts, and annual checks of every flat entrance door on a best-endeavours basis.
- All buildings with two or more domestic premises and common parts: residents must be given information on the importance of fire doors, not tampering with them, and reporting faults.
"Best endeavours" matters. You cannot force entry, but you must be able to show a genuine, repeated and documented attempt — letters, appointment cards, varied times, records of refusals. A blank against a flat number with no history behind it is not a defence.
What a flat entrance door check covers
Under BS 8214:2026 practice, each door is assessed for:
- Certification evidence — a label or plug identifying a third-party certified doorset (BM TRADA Q-Mark, Certifire or equivalent). Legacy doors with no evidence are assessed on their construction and condition and usually flagged for upgrade or replacement.
- Gaps — about 3 mm at head and jambs (±1 mm), threshold gap in line with the certification.
- Intumescent strips and smoke seals — continuous, correct size, undamaged, unpainted.
- Hinges — three or more, BS EN 1935 Grade 13, all screws present and correct length.
- Self-closer — a BS EN 1154 device that closes and latches the door fully from any angle, including from a small opening.
- Ironmongery and penetrations — fire-rated locks, letterplates and spy holes only; no unauthorised holes, no cat flaps, no non-rated numerals screwed through the leaf.
- Leaf and frame condition — no splits, warping, delamination or impact damage; the frame secure in the opening.
Accessibility applies too: Approved Document M limits the opening force at the leading edge to 30 N through the first 30 degrees and 22.5 N thereafter, so a closer wound up to overcome a badly hung door can create its own compliance problem.
The defects we find most in flats
- Closers disconnected, removed or adjusted so the door stops short of latching.
- Doors wedged or propped by residents, particularly on moving-in days and in corridors.
- Non-rated replacement letterplates and spy holes fitted by residents.
- Draught excluders and brush strips added at the threshold, altering the tested gap.
- Repeated redecoration burying the smoke seals in paint.
- Gaps at the hinge side over 4 mm from a dropped leaf.
Who pays for what
In most leasehold arrangements, the flat entrance door is treated as part of the demised premises but its fire performance is a landlord/building safety matter. In practice, responsible persons in England increasingly programme and fund flat entrance door replacement centrally, because the building's compliance depends on doors they do not directly control. Whatever the tenure, the checks and the record-keeping remain the responsible person's duty.
How we work with blocks
Stark Contracts carries out quarterly common-part inspections and annual flat entrance door surveys with digital reporting: every door referenced, photographed and scored, with a prioritised remedial schedule you can hand straight to an enforcement officer. We complete the remedials ourselves and install certified FD30S doorsets where replacement is the right call, working around residents with agreed access windows.
Call 01522 775570 or email Enquiries@Starkcontracts.co.uk for a survey of your block.